| DRIVE TYPE | DIRECT |
| ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| AIR FLOW RATE | 90.0 CUBIC FEET PER MINUTE NOMINAL |
| AMBIENT TEMP AT FULL RATED POWER | 55.0 CELSIUS |
| DIAMETER | 2.620 INCHES NOMINAL |
| ENVIRONMENTAL PROTECTION | DUSTPROOF AND HUMIDITY PROOF AND SALT SPRAY RESISTANT AND VIBRATION PROOF |
| FEATURES PROVIDED | SAFETY IMPELLER GUARD |
| FLOW DIRECTION | OUTWARD |
| FREQUENCY IN HERTZ | 400.0 |
| HOUSING INSIDE DIAMETER | 2.660 INCHES NOMINAL |
| INCLOSURE TYPE | FULLY INCLOSED |
| LENGTH | 2.469 INCHES NOMINAL |
| MATERIAL | ALUMINUM ALLOY OVERALL |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 RING |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 16000.0 |
| PHASE | THREE |
| PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| PRIME MOVER POWER RATING | 0.100 HORSEPOWER |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| QUANTITY | 1 |
| ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| SPEED ADJUSTMENTS | SINGLE SPEED |
| STAGE QUANTITY | 1 |
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 1.2 INCHES OF WATER |
| STYLE DESIGNATOR | FIXED |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 200.0 AC |