| AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS25.0 CELSIUS |
| BODY LENGTH | 0.630 INCHES MAXIMUM0.630 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 0.220 INCHES MAXIMUM0.220 INCHES MAXIMUM |
| CUBIC MEASURE | 0.018 CUBIC INCHES |
| INCLOSURE TYPE | UNINCLOSED |
| MAXIMUM OPERATING TEMP | 140.0 CELSIUS140.0 CELSIUS |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 11.011.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -11.0 TO 11.0 FOURTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 THIRD RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.0 TO 13.0 FIFTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 SECOND RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 SIXTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.0 TO 16.0 FIRST RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.5 TO 16.5 SEVENTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.0 TO 18.0 EIGHTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.1 TO 19.1 NINTH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.5 TO 20.5 TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 15.6 OHMS THIRD RESISTANCE-TEMPERATURE POINT15.6 OHMS THIRD RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.5 OHMS TENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 23.7 OHMS SECOND RESISTANCE-TEMPERATURE POINT23.7 OHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.1 OHMS FIFTH RESISTANCE-TEMPERATURE POINT8.1 OHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.85 OHMS FOURTH RESISTANCE-TEMPERATURE POINT9.85 OHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| ZERO POWER RESISTANCE | 10.000 OHMS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.0 OHMS NINTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.8 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT3.8 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 38.8 OHMS FIRST RESISTANCE-TEMPERATURE POINT38.8 OHMS FIRST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.7 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT4.7 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.1 OHMS SIXTH RESISTANCE-TEMPERATURE POINT6.1 OHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | ROD |
| SURFACE TREATMENT | SOLDER TERMINAL |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT120.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 140.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT140.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT20.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 40.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT40.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT60.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT80.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT-20.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT100.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.032 INCHES NOMINAL0.032 INCHES NOMINAL |
| TERMINAL LENGTH | 1.380 INCHES MINIMUM1.380 INCHES MINIMUM |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THERMAL TIME CONSTANT IN SECONDS | 25.025.0 |