5977-01-072-2035 BRUSH,ELECTRICAL CONTACT Index 5920-01-072-2037 ARRESTER,LIGHTNING

National Stock Number:
5905-01-072-2036

Federal Supply Class:
5905

National Item Identification Number:
010722036

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
101883-00188932NORTHROP GRUMMAN CORP PRECISION PRODUCTS PLANT


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS25.0 CELSIUS
BODY OUTSIDE DIAMETER0.250 INCHES MAXIMUM0.250 INCHES MAXIMUM
BODY WIDTH0.095 INCHES MAXIMUM0.095 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP200.0 CELSIUS200.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING350.00 MILLIWATTS350.00 MILLIWATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.02.0
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-2.0 TO 2.0 ALL RESISTANCE-TEMPERATURE POINTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.166 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT1.166 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP120.3 OHMS NINTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP194.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT194.0 OHMS EIGHTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.482 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT2.482 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP598.3 OHMS SIXTH RESISTANCE-TEMPERATURE POINT598.3 OHMS SIXTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP78.0 OHMS TENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP88.27 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT88.27 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-2.0 TO 2.0
ZERO POWER RESISTANCE4.002 KILOHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP26.52 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT26.52 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP329.9 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT329.9 OHMS SEVENTH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP5.833 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT5.833 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORDISK
SURFACE TREATMENTSOLDER TERMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-18.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT-18.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT-40.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER104.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT104.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER127.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT127.0 CELSIUS EIGHTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER149.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT149.0 CELSIUS NINTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER16.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT16.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER171.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT171.0 CELSIUS TENTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER38.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT38.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER60.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT60.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER82.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT82.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.01003 INCHES NOMINAL0.01003 INCHES NOMINAL
TERMINAL LENGTH11.750 INCHES NOMINAL11.750 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS30.030.0


Click here to Register for Free 30-day Trial