3120-00-124-4710 BEARING,WASHER,THRUST Index 5915-00-124-4714 FILTER,BAND PASS

National Stock Number:
5915-00-124-4713

Federal Supply Class:
5915

National Item Identification Number:
001244713

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
113000003131196STELLANT PST CORP.
SMA75320331196STELLANT PST CORP.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS11000000.0
BODY LENGTH3.030 INCHES MINIMUM AND 3.070 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.690 INCHES MINIMUM AND 0.710 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS70.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK AND 21.0 MINIMUM BLANK FIRST FUNCTION
FEATURES PROVIDEDSHOCK RESISTANT
FREQUENCY BAND WIDTH PER FUNCTION7.20 GIGAHERTZ BLANK AND 7.70 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH3.770 INCHES MINIMUM AND 3.850 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+7.0 TO 37.8 CELSIUS
OVERALL HEIGHT0.932 INCHES MINIMUM AND 0.942 INCHES MAXIMUM
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION7.45 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.80 GIGAHERTZ BLANK AND 7.20 GIGAHERTZ BLANK AND 7.70 GIGAHERTZ BLANK AND 7.90 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION7.2 GIGAHERTZ BLANK AND 7.7 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED