Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
398446-100752L3HARRIS TECHNOLOGIES, INC.
4BB440-25NN23042TRILITHIC, INC.


Techincal Specification:
BODY OUTSIDE DIAMETER0.375 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
FREQUENCY BAND WIDTH PER FUNCTION427.50 MEGAHERTZ BLANK AND 452.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH3.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-40.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION440.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ5.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION260.00 MEGAHERTZ BLANK AND 427.50 MEGAHERTZ BLANK AND 452.00 MEGAHERTZ BLANK AND 550.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION427.5 MEGAHERTZ BLANK AND 452.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED