5915-00-769-3106 FILTER,BAND PASS Index 5950-00-769-3108 REACTOR

National Stock Number:
5915-00-769-3107

Federal Supply Class:
5915

National Item Identification Number:
007693107

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
4784482340L3HARRIS TECHNOLOGIES, INC.


Techincal Specification:
BODY HEIGHT2.000 INCHES MAXIMUM
BODY LENGTH1.375 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.375 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS24.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.750 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION78.00 KILOHERTZ BLANK AND 84.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 SOLDER STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 SOLDER STUD GROUND THIRD FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.138 INCHES
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.317 INCHES MAXIMUM
REFERENCE FREQUENCY PER FUNCTION81.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION60.00 KILOHERTZ BLANK AND 78.00 KILOHERTZ BLANK AND 84.00 KILOHERTZ BLANK AND 102.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE