5915-01-014-4833 FILTER,BAND PASS Index 5915-01-014-4835 FILTER,BAND PASS

National Stock Number:
5915-01-014-4834

Federal Supply Class:
5915

National Item Identification Number:
010144834

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
154036P494117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
P804C11869ST OLEKTRON CORP


Techincal Specification:
BODY HEIGHT0.570 INCHES MINIMUM AND 0.590 INCHES MAXIMUM
BODY LENGTH1.750 INCHES MINIMUM AND 1.765 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.850 INCHES MINIMUM AND 0.865 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.440 INCHES MINIMUM AND 1.460 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION79.965 MEGAHERTZ BLANK AND 80.035 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION5.6 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OVERALL HEIGHT0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.086 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION5.6 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION80.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION75.00 MEGAHERTZ BLANK AND 79.965 MEGAHERTZ BLANK AND 80.035 MEGAHERTZ BLANK AND 85.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial