5998-01-029-2636 CIRCUIT CARD ASSEMBLY Index 5998-01-029-2638 CIRCUIT CARD ASSEMBLY

National Stock Number:
5915-01-029-2637

Federal Supply Class:
5915

National Item Identification Number:
010292637

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2887382-710001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
2887382-73B150RAYTHEON COMPANY
CF-5452-702533LEIGH INSTRUMENTS LTD FREQUENCY CONTROL DIV C R SNELGROVE CO
6597A730988THERMO ELECTRON CORPORATION DBA IEC CENTRIFUGE DIV LABORATORY EQUIPMENT DIVSION
2887382-749956RAYTHEON COMPANY
2887382-754X10RAYTHEON COMPANY
FE-F1190714844FREQUENCY ELECTRONICS INC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS20000.0
BODY HEIGHT0.960 INCHES MAXIMUM
BODY LENGTH1.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH0.875 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM BLANK AND 3.0 MINIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION5.458 MEGAHERTZ BLANK AND 5.464 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION3.01 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OVERALL HEIGHT1.355 INCHES MINIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION5.461 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.454 MEGAHERTZ BLANK AND 5.458 MEGAHERTZ BLANK AND 5.464 MEGAHERTZ BLANK AND 5.468 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE