| ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.530 MINIMUM AND 5.600 MAXIMUM ALL LOCATIONS |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.855 INCHES NOMINAL |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC ALL LOCATIONS |
| SPECIAL TEST FEATURES | NAVORD OD36190 |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| POLE QUANTITY | 2 |
| THREAD SERIES DESIGNATOR | UNEF |
| RESET METHOD | MANUAL |
| TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
| BUSHING LENGTH | 0.340 INCHES NOMINAL |
| BODY WIDTH | 1.250 INCHES NOMINAL |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| THREAD QUANTITY PER INCH | 32 |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC ALL LOCATIONS |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
| TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SPECIAL TEST FEATURES |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES DC ALL LOCATIONS |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| BODY LENGTH | 1.531 INCHES NOMINAL |
| ACTUATOR FUNCTION | RESET |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.120 MINIMUM AT 200 PCT AND 1.300 MAXIMUM AT 200 PCT AND 0.030 MINIMUM AT 300 PCT AND 0.450 MAXIMUM AT 300 PCT AND 0.010 MINIMUM AT 400 PCT AND 0.220 MAXIMUM AT 400 PCT ALL LOCATIONS |
| NOMINAL THREAD SIZE | 0.375 INCHES |