| BODY HEIGHT | 3.437 INCHES MAXIMUM |
| BODY LENGTH | 4.515 INCHES MINIMUM AND 4.546 INCHES MAXIMUM |
| BODY WIDTH | 2.984 INCHES MINIMUM AND 3.015 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.484 INCHES MINIMUM AND 3.515 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.109 INCHES MINIMUM AND 2.140 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | MUST FUNCTION IN A LIQUID COOLED POWER SUPPLY PER FC 77 |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING VOLTAGE | 416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 22 TURRET |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |