| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 3.150 INCHES MINIMUM AND 3.850 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 3.500 INCHES MAXIMUM AS SUPPLIED |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 3.650 INCHES MINIMUM AND 4.470 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 4.060 INCHES MAXIMUM AS SUPPLIED |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 25.0 MINIMUM AND 35.0 MAXIMUM AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 20.0 MAXIMUM AS SUPPLIED |
| COLOR | BLACK |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 10000.0 |
| FIRST BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH INSIDE DIAMETER | 1.050 INCHES MINIMUM AS SUPPLIED |
| FIRST BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
| FIRST BRANCH WALL THICKNESS | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FLEXIBILITY | FLEXIBLE |
| MAIN BODY INSIDE DIAMETER | 1.000 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| MAIN BODY INSIDE DIAMETER | 2.190 INCHES MINIMUM AS SUPPLIED |
| MAIN BODY OVERALL LENGTH | 6.800 INCHES MINIMUM AND 8.320 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| MAIN BODY OVERALL LENGTH | 8.330 INCHES MAXIMUM AS SUPPLIED |
| MAIN BODY WALL THICKNESS | 0.140 INCHES MINIMUM AND 0.220 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| MAIN BODY WALL THICKNESS | 0.180 INCHES MAXIMUM AS SUPPLIED |
| MATERIAL | RUBBER CHLOROPRENE CLASS CR LOCATION NOT OTHERWISE SPECIFIED |
| MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
| SECOND BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| SECOND BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
| SECOND BRANCH WALL THICKNESS | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| STYLE DESIGNATOR | TRANSITION-1 TO 3 CABLES |
| TEMP RATING | -55.0 CELSIUS AND 80.0 CELSIUS |
| THIRD BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| THIRD BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
| THIRD BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
| THIRD BRANCH WALL THICKNESS | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |