| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| FLANGE QUANTITY | 2 |
| FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
| FLANGE STYLE | CONTACT TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT |
| ALUMINUM ALLOY ALL FLANGE |
| WAVEGUIDE OUTSIDE WIDTH | 1.000 INCHES NOMINAL |
| WAVEGUIDE INSIDE WIDTH | 0.900 INCHES NOMINAL |
| WAVEGUIDE INSIDE HEIGHT | 0.400 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 0.500 INCHES NOMINAL |
| BEND ANGLE IN DEG | 90.0 FIRST BEND H-PLANE |
| 90.0 SECOND BEND E-PLANE |
| SURFACE TREATMENT | OXIDE FILM ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES |
| PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM AND |
| 0.903 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND |
| 0.403 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 2.070 INCHES MINIMUM AND |
| 2.110 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.570 INCHES MINIMUM AND |
| 1.610 INCHES MAXIMUM ALL FLANGES |
| FLANGE DEPTH | 0.480 INCHES MINIMUM AND |
| 0.520 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING HOLE DIAMETER | 0.167 INCHES MINIMUM AND |
| 0.171 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY |
| MAXIMUM OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAGE |
| INSERTION LOSS IN DECIBELS | 0.05 |
| VOLTAGE STANDING WAVE RATIO | 1.10 |
| SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 10001 |
| DESIGN CONTROL REFERENCE | 2836029 |