| BEND ANGLE IN DEG | 90.0 SINGLE BEND E-PLANE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.922 INCHES MINIMUM AND 0.953 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) ALL FLANGES SINGLE CONNECTION FACILITY |
| FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY |
| FLANGE INSIDE WIDTH | 1.253 INCHES MINIMUM AND 1.256 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.628 INCHES MINIMUM AND 0.631 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM FIRST FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | COVER TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| INSERTION LOSS IN DECIBELS | 0.05 |
| MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT |
| MATERIAL | ALUMINUM ALLOY ALL FLANGE |
| OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| SPECIAL FEATURES | TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
| VOLTAGE STANDING WAVE RATIO | 1.05 |
| WAVEGUIDE OFFSET DISTANCE | 1.500 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
| WAVEGUIDE LONGER OFFSET DISTANCE | 1.625 INCHES NOMINAL |
| STYLE DESIGNATOR | CORNER TYPE |
| SURFACE TREATMENT | OXIDE FILM ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |